Darmowa dostawa z usługą Inpost oraz Orlen od 299.00 zł
InPost 13.99 DPD 25.99 Paczkomat 13.99 Poczta Polska 18.99 ORLEN Paczka 10.99

Backward Amplification and Beam Cleanup of a Raman Fiber Laser Oscillator Using a Multi-Mode Graded Index Fiber Amplifier

Język AngielskiAngielski
Książka Miękka
Książka Backward Amplification and Beam Cleanup of a Raman Fiber Laser Oscillator Using a Multi-Mode Graded Index Fiber Amplifier Jesse D S Morgan
Kod Libristo: 08139000
Wydawnictwo Biblioscholar, wrzesień 2012
This thesis tested a CW fiber-based Raman amplifier implemented in a backward pumped geometry. To cr... Cały opis
? points 150 b
255.47
Dostępna u dostawcy Wysyłamy za 15-20 dni

30 dni na zwrot towaru


Mogłoby Cię także zainteresować


Fettered Lyn Gala / Miękka
common.buy 70.74
Dead and Buried. a Romance of Christchurch. Mary Harriette Pickersgill Cunliffe / Miękka
common.buy 94.20

This thesis tested a CW fiber-based Raman amplifier implemented in a backward pumped geometry. To create a seed for the amplifier, a CW Nd:YAG laser operating at 1.064??m was used to pump a 50??m multimode graded index fiber using fiber Bragg gratings to create a Raman Fiber Laser (RFL) Oscillator with a Stokes beam at 1.116??. The Stokes beam was then used to seed two lengths, 5.3km and 2.5km, of 50?? multimode graded index fiber. The fiber amplifier was pumped by a second CW Nd:YAG laser in the backward geometry. Spectral data taken for both fibers indicated that the backward geometry avoided the problem of Four Wave Mixing (FWM) present in the forward geometry for amplification. Gain and beam cleanup were observed in both lengths of fiber. An M2 of 6.7 0.2 was observed in the 5.3km fiber with 5 W of pumping. With 9 W of pump, a gain of 321.3% was observed, but severe attenuation due to the length of fiber prevented overall amplification of the seed with the available pump power. The 2.5km fiber produced an M2 of 3.9 0.5 with 5 W of pumping. With 10 W of pump, a gain of 241.8% and overall amplification of 153.1% was observed.

Informacje o książce

Pełna nazwa Backward Amplification and Beam Cleanup of a Raman Fiber Laser Oscillator Using a Multi-Mode Graded Index Fiber Amplifier
Język Angielski
Oprawa Książka - Miękka
Data wydania 2012
Liczba stron 70
EAN 9781249496793
ISBN 9781249496793
Kod Libristo 08139000
Wydawnictwo Biblioscholar
Waga 141
Wymiary 189 x 246 x 4
Podaruj tę książkę jeszcze dziś
To łatwe
1 Dodaj książkę do koszyka i wybierz „dostarczyć jako prezent” 2 W odpowiedzi wyślemy Ci bon 3 Książka dotrze na adres obdarowanego

Logowanie

Zaloguj się do swojego konta. Nie masz jeszcze konta Libristo? Utwórz je teraz!

 
obowiązkowe
obowiązkowe

Nie masz konta? Zyskaj korzyści konta Libristo!

Dzięki kontu Libristo będziesz mieć wszystko pod kontrolą.

Utwórz konto Libristo