Darmowa dostawa z usługą Inpost oraz Orlen od 299.00 zł
InPost 13.99 DPD 25.99 Paczkomat 13.99 ORLEN Paczka 10.99 Poczta Polska 18.99

Blind Deconvolution of Anisoplanatic Images Collected by a Partially Coherent Imaging System

Język AngielskiAngielski
Książka Miękka
Książka Blind Deconvolution of Anisoplanatic Images Collected by a Partially Coherent Imaging System Adam MacDonald
Kod Libristo: 08131952
Wydawnictwo Biblioscholar, wrzesień 2012
Coherent imaging systems offer unique benefits to system operators in terms of resolving power, rang... Cały opis
? points 150 b
255.29
Dostępna u dostawcy Wysyłamy za 15-20 dni

30 dni na zwrot towaru


Mogłoby Cię także zainteresować


Der Zugang zum psychosomatischen Denken B. Luban-Plozza / Miękka
common.buy 331.09
Bush Pilot's Mayday Ken Forscutt / Miękka
common.buy 96.33

Coherent imaging systems offer unique benefits to system operators in terms of resolving power, range gating, selective illumination and utility for applications where passively illuminated targets have limited emissivity or reflectivity. In contrast to incoherent imaging systems, partially coherent illumination causes difficulty during image processing due to high levels of image speckle caused by constructive and de- structive interference effects unique to the highly coherent illumination source. Image speckle is caused by the random phase delays that occur due to target roughness and the turbulent atmosphere between the remote target and optical system. To combat such effects, a number of short-exposure images are combined by incoherent averaging to arrive at an image that has greatly decreased levels of speckle. Unfortunately, such average images suffer from decreased spatial resolution due to blur resulting from atmospheric distortion. Effective image restoration may be realized by inverse filtering the recovered average image with an optical transfer function that describes the overall optical system and atmospheric turbulence. In cases where it is inconvenient or impossible to measure the parameters of this evolving function, blind deconvolution algorithms may be applied to estimate both the unknown remote scene reflectance, as well as the unknown system transfer function. This research proposes a novel blind deconvolution algorithm that is based on a maximum a posteriori Bayesian estimator constructed upon a physically-based statistical model for the intensity of the partially coherent light at the imaging detector. The estimator is initially constructed using a shift- invariant system model, and is later extended to the case of a shift-variant optical system by the addition of a transfer function term that quantifies optical blur for given field-of-views and atmospheric conditions. The estimators are evaluated using both synthetically generated imagery,

Informacje o książce

Pełna nazwa Blind Deconvolution of Anisoplanatic Images Collected by a Partially Coherent Imaging System
Język Angielski
Oprawa Książka - Miękka
Data wydania 2012
Liczba stron 174
EAN 9781249374480
ISBN 9781249374480
Kod Libristo 08131952
Wydawnictwo Biblioscholar
Waga 322
Wymiary 189 x 246 x 9
Podaruj tę książkę jeszcze dziś
To łatwe
1 Dodaj książkę do koszyka i wybierz „dostarczyć jako prezent” 2 W odpowiedzi wyślemy Ci bon 3 Książka dotrze na adres obdarowanego

Logowanie

Zaloguj się do swojego konta. Nie masz jeszcze konta Libristo? Utwórz je teraz!

 
obowiązkowe
obowiązkowe

Nie masz konta? Zyskaj korzyści konta Libristo!

Dzięki kontu Libristo będziesz mieć wszystko pod kontrolą.

Utwórz konto Libristo