Darmowa dostawa z usługą Inpost oraz Orlen od 299.00 zł
InPost 13.99 DPD 25.99 Paczkomat 13.99 Poczta Polska 18.99 ORLEN Paczka 10.99

Decontamination Strategy for Large Area And/Or Equipment Contaminated with Chemical and Biological Agents Using a High Energy ARC Lamp (Heal)

Język AngielskiAngielski
Książka Miękka
Książka Decontamination Strategy for Large Area And/Or Equipment Contaminated with Chemical and Biological Agents Using a High Energy ARC Lamp (Heal) Richard Schoske
Kod Libristo: 08134903
Wydawnictwo Biblioscholar, wrzesień 2012
A strategy for the decontamination of large areas and or equipment contaminated with Biological Warf... Cały opis
? points 150 b
255.47
Dostępna u dostawcy Wysyłamy za 15-20 dni

30 dni na zwrot towaru


Mogłoby Cię także zainteresować


A strategy for the decontamination of large areas and or equipment contaminated with Biological Warfare Agents (BWAs) and Chemical Warfare Agents (CWAs) was demonstrated using a High Energy Arc Lamp (HEAL) photolysis system. This strategy offers an alternative that is potentially quicker, less hazardous, generates far less waste, and is easier to deploy than those currently fielded by the Department of Defense (DoD). For example, for large frame aircraft the United States Air Force still relies on the combination of weathering (stand alone in environment), air washing (fly aircraft) and finally washing the aircraft with Hot Soapy Water (HSW) in an attempt to remove any remaining contamination. This method is laborious, time consuming (upwards of 12+ hours not including decontamination site preparation), and requires large amounts of water (e.g., 1,600+ gallons for a single large frame aircraft), and generates large amounts of hazardous waste requiring disposal. The efficacy of the HEAL system was demonstrated using diisopropyl methyl phosphonate (DIMP) a G series CWA simulant, and Bacillus globigii (BG) a simulant of Bacillus anthracis. Experiments were designed to simulate the energy flux of a field deployable lamp system that could stand-off 17 meters from a 12m2 target area and uniformly expose a surface at 1360 W/m2. The HEAL system in the absence of a catalyst reduced the amount of B. globigii by five orders of magnitude at a starting concentration of 1.63 x 107 spores. In the case of CWA simulants, the HEAL system in the presence of the catalyst TiO2 effectively degraded DIMP sprayed onto a 100mm diameter Petri dish in 5 minutes.

Informacje o książce

Pełna nazwa Decontamination Strategy for Large Area And/Or Equipment Contaminated with Chemical and Biological Agents Using a High Energy ARC Lamp (Heal)
Język Angielski
Oprawa Książka - Miękka
Data wydania 2012
Liczba stron 26
EAN 9781249414636
ISBN 9781249414636
Kod Libristo 08134903
Wydawnictwo Biblioscholar
Waga 68
Wymiary 189 x 246
Podaruj tę książkę jeszcze dziś
To łatwe
1 Dodaj książkę do koszyka i wybierz „dostarczyć jako prezent” 2 W odpowiedzi wyślemy Ci bon 3 Książka dotrze na adres obdarowanego

Logowanie

Zaloguj się do swojego konta. Nie masz jeszcze konta Libristo? Utwórz je teraz!

 
obowiązkowe
obowiązkowe

Nie masz konta? Zyskaj korzyści konta Libristo!

Dzięki kontu Libristo będziesz mieć wszystko pod kontrolą.

Utwórz konto Libristo